EasyManua.ls Logo

Visonic POWERMASTER 10 - Reading the Event Log

Visonic POWERMASTER 10
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide 85
6 READING THE EVENT LOG
Events are stored in the event log. You can access this log and review the events, one by one. If the event log
fills up completely, the oldest event is deleted upon registration of each new event.
The date and time of occurrence are memorized for each event.
When reading the event log, events are shown in chronological order - from the newest to the oldest. Access to the
event log is provided by clicking the
button and not through the installer’s menu. The reading and erasing
process of the event log is shown below.
Step 1
Step 2
Step 3
Step 4
Step 5
In normal operating
mode
[1] Enter Installer Code [2] Reviewing Events
[3] Scroll List of Events [4]
Continue
to Step
6.
Step 6
Step 7
Step 8
Step 9
CLEAR EVENT LOG
display
[6] Erase the Event Log
[7] Event Log is erased [8] Returns to normal
operating mode
[9]
- Reading Events
[1]
While the system is in the normal operating mode, press the key.
Reading the Event Log
[2]
Enter the current Installer Code and then press to enter "LIST OF EVENTS".
[3]
The latest event is shown.
The event is displayed in two parts, for example, "Z13 alarm" then "09/02/10 3:37 P".
[4]
Press repeatedly to scroll through the list of events.
Erasing and Exiting the Event Log:
[6]
From anywhere within the event log, press the button and then press .
[7]
At this stage in the procedure, clicking the or buttons will take you to “<OK> TO EXIT
without erasing the event log. Clicking the button will revert to “CLEAR EVENT LOG”.
Press the button to erase the event log.
[8]
The system erases the event log
[9]
Press to revert to normal operating mode.
Clicking the button repeatedly at any stage in the procedure takes you one level up with each
click. Clicking the button will take you to “<OK> TO EXIT”.
09/02/10 3:37 P
CLEAR EVENT LOG <OFF> to delete <OK> TO EXIT READY 00:00
07/02/10 11:49 A
SR2 TAMPER
-
ALARM
Z13 alarm
LIST OF EVENTS
ENTER CODE:
READY 00:00