EasyManua.ls Logo

Visonic POWERMASTER 10 - E2. SIA Event Codes; E3. Understanding the Scancom Reporting Protocol Data Format

Visonic POWERMASTER 10
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100 D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
E2. SIA Event Codes
Code Definition
Code Definition
AR
AC Restore
LR
Phone Line Restore
AT
AC Trouble
LT
Phone Line Trouble
BA
Burglary
Alarm
OP
Opening Report
BB
Burglary Bypass
OT
Fail to Arm
BC
Burglary Cancel
PA
Panic Alarm
BR
Burglary Restore
PR
Panic Restore
BT
Burglary Trouble / Jamming
QA
Emergency Alarm
BV
Burglary Verified
RN
Engineer Reset
BZ
Inactive event
RP
Auto
matic Test
CF
Forced Closing
RX
Manual Test
CG
Armed home
RY
Exit from Manual Test
CI
Fail to Close
TA
Tamper Alarm
CL
Armed Away
TR
Tamper Restore
CP
Auto Arm
UJ
Detector mask restore
CR
Recent Close
YM
System battery disconnect
EA
Door Open
UT
Detector mask
FA
Fire Alarm
WA
Flood alarm
FT
Fire Detector Clean
WR
Flood alarm restore
FJ
Fire detector trouble
XR
Sensor Battery Restore
FR
Fire Restore
XT
Sensor Battery Trouble
GA
Gas alarm
YR
System Battery Restore
GR
Gas alarm restore
YT
System Battery
Trouble / Disconnection
GT
Gas trouble
YX
Service Required
GJ
Gas trouble restore
ZA
Freeze
alarm
HA
Holdup Alarm (duress)
ZH
Freeze alarm restore
KA
Heat alarm
ZJ
Freeze
trouble
restore
KH
Heat alarm
restore
ZR
Freeze restore
KT
Heat
trouble
ZT
Freeze trouble
KJ
Heat
trouble restore
E3. Understanding the Scancom Reporting Protocol Data Format
The SCANCOM data format consists
of 13 decimal digits divided into 4
groups, from left to right, as shown at
the right side.
Each channel is associated with a
specific event as follows:
1
st
"C": Fire
2
nd
"C": Personal attack
3
rd
"C": Intruder
4
th
"C": Open/close
5
th
"C": Alarm cancel
6
th
"C": Emergency
7
th
"C": Second alarm
8
th
"C": Trouble messages
Account
Code
aaaa
Channels
1 - 4
cccc
Channels
5 - 8
cccc
S
System Status:
no trouble, test,
low battery
- - - - - - - -
The digit in this position
conveys the status of
channel 1
The digit in this position
conveys the status of
channel 8
Scancom Data Format

Table of Contents