86 D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
APPENDIX A. Specifications
A1. Functional
PowerMaster-10 PowerMaster-30
Zones Number 30 wireless zones (including 1 hardwired
input).
Up to 64 wireless zones, (including 2
hardwired inputs).
Hardwired Zone
Requirements
2.2 kE.O.L. resistance (max. resistance
of wires 220 Ω).
2.2 kE.O.L. resistance (max. resistance
of wires 220 Ω).
Installer and User
Codes
1 master installer (9999 by default)*
1 installer (8888 by default)*
1 master user, no. 1 (1111 by default)
Users nos. 2 - 8
* Codes must not be identical
1 master installer (9999 by default)*
1 installer (8888 by default)*
1 master user, no. 1 (1111 by default)
Users nos. 2 - 48
* Codes must not be identical
Control Facilities - Integral keypad, wireless keyfobs and
keypads
- SMS commands via optional GSM/GPRS
module.
- Remote control by telephone.
Note: For SIA CP-01 compliance, when
using KF-234 PG2 an external siren must
also be used.
- Integral keypad, wireless keyfobs and
keypads
- SMS commands via optional GSM/GPRS
module.
- Remote control by telephone.
Display Single line, backlit 16-large character LCD. Single line, backlit 16-large character LCD.
Arming Modes AWAY, HOME, AWAY-INSTANT, HOME-
INSTANT, LATCHKEY, FORCED,
BYPASS.
AWAY, HOME, AWAY-INSTANT, HOME-
INSTANT, LATCHKEY, FORCED,
BYPASS.
Alarm Types Silent alarm, personal panic/emergency
alarm, burglary alarm, gas alarm, fire alarm
and flood alarm.
Silent alarm, personal panic/emergency
alarm, burglary alarm, gas alarm, fire alarm
and flood alarm.
Siren Signals Continuous (intrusion / 24 hours / panic);
triple pulse – short pause - triple pulse...
(fire);
four pulses – long pause – four pulses...
(gas);
long pulse – long pause – long pulse...
(flood).
Continuous (intrusion / 24 hours / panic);
triple pulse – short pause - triple pulse...
(fire);
four pulses – long pause – four pulses...
(gas);
long pulse – long pause – long pulse...
(flood).
Siren (bell)
Timeout
Programmable (4 min. by default) Programmable (4 min. by default)
Internal Sounder
Output
At least 85 dBA at 10 ft (3 m) At least 85 dBA at 10 ft (3 m)
Supervision Programmable time frame for inactivity
alert
Programmable time frame for inactivity
alert
Special
Functions
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over
Telephone, GSM /GPRS connections.
- Calling for help by using an emergency
transmitter.
- Tracking inactivity of elderly, physically
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over
Telephone, GSM /GPRS connections.
- Calling for help by using an emergency
transmitter.
- Tracking inactivity of elderly, physically

Table of Contents

Other manuals for Visonic POWERMASTER 10

Related product manuals