D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide  87 
 
handicapped and infirm people.  handicapped and infirm people. 
- Message center (recording and playback) 
- Two-way voice communication 
Data Retrieval  Alarm memory, trouble, event log  Alarm memory, trouble, event log 
Real Time Clock 
(RTC) 
The control panel keeps and displays time 
and date. This feature is also used for the log 
file by providing the date and time of each 
event 
The control panel keeps and displays time 
and date. This feature is also used for the log 
file by providing the date and time of each 
event 
Battery Test  Once every 10 seconds  Once every 10 seconds 
A2. Wireless 
 
PowerMaster-10  PowerMaster-30 
RF Network  PowerG – 2-way synchronized Frequency 
Hopping (TDMA / FHSS) 
PowerG – 2-way synchronized Frequency 
Hopping (TDMA / FHSS) 
Frequency bands 
(MHz) 
433 – 434  868 - 869  912 - 919  433 – 434  868 - 869  912 - 919 
Hopping 
frequencies 
8  4  50  8  4  50 
Region 
Worldwide  Europe   North 
America 
and 
selected 
countries 
Worldwide  Europe   North 
America 
and 
selected 
countries 
Encryption  AES-128  AES-128 
A3. Electrical 
  PowerMaster-10  PowerMaster-30 
External AC/AC 
adaptor 
Europe: 230VAC 50Hz input, 9VAC 
700mA output. 
USA: 120VAC 60Hz input, 9VAC 1000mA 
output. 
NA 
External AC/DC 
adaptor 
-  External (wall-mounted) switching power 
supply 100VAC to 240VAC, 50/60 Hz, 0.5A 
/ 12.5 VDC, 1.6A 
Internal AC/DC  Internal switching power supply: 
Input: 100-240VAC, 0.12 A Max. 
Output: 7.5VDC, 1.2A Max. 
Internal switching power supply: 
Input: 100-240VAC, 0.5A 
Output: 12.5 VDC, 1.6A. 
Current Drain  Approx. 70 mA standby, 1200 mA peak at 
full load. 
Approx. 40 mA standby, 1400 mA at full 
load. 
Backup Battery 
Pack 
4.8V 1300 mAh, rechargeable NiMH 
battery pack, p/n GP130AAM4YMX, 
manufactured by GP or equivalent 
Caution! Risk of explosion if battery is 
replaced by an incorrect type. Dispose of 
used batteries according to the 
manufacturer's instructions. 
Note: For compliance with UL standards 
the battery backup period shall exceed 24 
hours and 12 hours for compliance with CE 
standards. 
Backup Battery Options: