12 D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
2.2.4 Connecting to the Telephone Line
PHONE WIRING
Connect the telephone cable to the SET connector and connect the telephone line cable to the LINE connector
(through the desired wiring cable entry).
Note: The telephone cable should be no longer than 3 meters.
A
B
C
A. SET
B. LINE
C. Tel line wall jack
PHONE WIRING IN NORTH AMERICA
RJ-31X
1
2 3
4
5
6
7
E
F
H
F
G
G
J
E
H
K
A
B
C
D
I
A. SET
G. Green
B. LINE
H. Brown
C. RJ-31X cord I. RJ-31X jack
D. 8-position RJ-31X plug J. Line from street
E. Gray
K. House phones
F. Red
Figure 3.4 –Phone Wiring
This equipment is designed to be connected to the telephone network using an RJ11 connector which complies
with Part 68 rules and requirements adopted by ACTA and a properly installed RJ31X connector. See drawing
above for details.
In the case that RJ31X is not available (consult your telephone company or a qualified installer), the telephone
line should be connected to the PowerMaster-10 unit first and then all other home equipment should be
connected to the PowerMaster-10 "Phone" outlet.