D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide 51
Here you can activate the Screen Saver option and determine whether the status display
will resume following any key press (refresh by Key) or by entering a code (refresh by
Code). If refresh by Key is selected, the first pressing of any key (except Fire and
Emergency) will produce the status display and the second press will perform the key
function. Regarding the Fire and Emergency keys, the first key press will produce the
status display and will also perform the Fire/Emergency function. For further information
see User's Guide Chapter 1 "Screen Saver".
Option settings: OFF (default); refresh by code and refresh by key.
Note: To comply with EN requirements, "refresh by code" must be selected.
With Partition
enabled
Certain regulations require that the system status display will not be exposed to
unauthorized persons. The Screen Saver option (when activated) replaces the status
display with “PowerMaster-30” display if no key is pressed during more than 30 seconds.
Here you can activate the Screen Saver option and determine whether the status display
will resume following any key press (Text - by Key) or by entering a code (Text - by
Code). If Text by Key is selected, the first pressing of any key (except Fire and
Emergency) will produce the status display and the second press will perform the key
function. Regarding the Fire and Emergency keys, the first key press will produce the
status display and will also perform the Fire/Emergency function.
You can also determine that if no key is pressed during more than 30 seconds the date
and time will appear on the display. You can determine that normal display will return
after pressing the button followed by entering user code (Clock - by Code) or
after pressing any key (Clock - by Key).
For further information see User's Guide Chapter 1 "Screen Saver".
Option settings: OFF (default); Text - by code; Text - by Key; Clock - by Code; Clock -
by Key.
Note: To comply with EN requirements, "refresh by code" must be selected.
3.5.7 Configuring Jamming and Supervision (Missing device)
The following table provides you with a detailed description of each option and its Option settings. To select an
option and change its setting (configuration) – refer to section 3.5.1.
Option Configuration Instructions
Here you determine whether jamming (continuous interfering transmissions on the radio
network) will be detected and reported or not. If any of the jam detection options is
selected, the system will not allow arming under jamming conditions. The PowerMaster-
10 / PowerMaster-30 provides several jam detect and reporting options to comply with the
following standards:
Option Standard Detection and Reporting occurs when:
UL 20/20 USA There is continuous 20 seconds of jamming
EN 30/60 Europe
There is an accumulated 30 seconds of jamming within 60
sec.
Class 6
(30/60)
British
Standard
Like EN (30/60) but the event will be reported only if the
jamming duration exceeds 5 minutes.
disabled (default) No jamming detection and reporting.
Notes:
To comply with UL requirements, "UL 20/20" must be selected.
To comply with EN requirements, "EN 30/60" must be selected.
To comply with UK Class-6 requirements, " class 6 (30/60)" must be
selected.
Refers to PowerMaster-30 only
56:SCREEN SAVER
61:J
AM DETECT

Table of Contents

Other manuals for Visonic POWERMASTER 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER 10 and is the answer not in the manual?

Visonic POWERMASTER 10 Specifications

General IconGeneral
Communication ProtocolsPowerG
Frequency433-434 MHz, 868-869 MHz
System TypeWireless
CommunicationGSM
Remote ControlYes
Event Log1000 events
Partitions3
Humidity85% non-condensing
User Codes8
Backup BatteryNi-MH battery pack
Operating Temperature-10°C to +50°C