60  D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide 
 
 
If equipped with GSM or Broadband/PowerLink modules, the PowerMaster-10 / 
PowerMaster-30 can be programmed to report the event messages defined in Report 
Events option (option 01) to two IP Receivers Visonic model PowerManage. IP 
reporting can be performed via GPRS (IP) channel using SIA IP format or via 
Broadband IP channel using SIA IP or Visonic PowerNet format.  
Here you can enter the two respective IP addresses of the IP Receiver 1 located at the 
1
st
 Monitoring Station (21:IP RCVR 1) and IP Receiver 2 located at the 2
nd
 Monitoring 
Station (22:IP RCVR 2). 
Master Installer only
 
Enter the IP addresses (000.000.000.000) of IP Receiver 1 and IP Receiver 2 in their 
corresponding locations. 
 
 
 
 
 
If equipped with GSM module, the PowerMaster-10 / PowerMaster-30 can be 
programmed to report the event messages defined in Report Events option (option 01) 
to two SMS Receivers via the GSM SMS channel using a special SMS text format. For 
further details concerning the SMS text format please contact Visonic. 
Here you enter the two respective telephone numbers of the SMS Receiver 1 located at 
the 1
st
 Monitoring Station (26:SMS RCVR 1) and SMS Receiver 2 located at the 2
nd
 
Monitoring Station (27:SMS RCVR 2). 
Master Installer only 
Enter the telephone numbers of SMS Receiver 1 and SMS Receiver 2 in their 
corresponding locations (including area code – maximum 16 digits).  
 
Note: To enter the international prefix (
) at the 1
st
 digit – key-in [#]
[1]. 
 
 
 
 
 
The PowerMaster-10 / PowerMaster-30 can be programmed to report the event 
messages defined in Report Events option (option 01) to two Alarm Format Receivers 
(see options 16 & 17) via PSTN telephone line and/or GSM analog voice channel (if 
equipped with GSM module) using standard PSTN alarm formats (i.e. SIA, Contact-ID 
and Scancom).  
Here you select which of the reporting formats the system will use to report the events 
to the two Alarm Format Receivers PSTN/GSM RCVR 1 and PSTN/GSM RCVR 2. The 
Event Codes used for the reporting in each of the available formats are specified in 
APPENDIX E. Event Codes. 
Make sure that the receivers used by the Monitoring Stations are of the compatible 
models listed below and that the receiver used can receive the format you select. 
Compatible Alarm Format Receivers: 
Osborne-Hoffman model 2000; Ademco Model 685; FBII Model CP220; Radionics 
Model D6500; Sur-Gard Model SG-MLR2-DG and Silent Knight Model 9500. 
 
Master Installer only
 
Option settings: SIA (default); Scancom; SIA text and contact ID. 
 
 
 
 
 
Here you determine the number of times the system will retry to report to the Monitoring 
Station in case of failure to report via the PSTN telephone line connection.  
 
Option settings: 2 attempts; 4 attempts (default); 8 attempts; 12 attempts and 
16 attempts. 
 
 
 
 
 
Here you determine the number of times the system will retry to report to the Monitoring 
Station in case of failure to report via the cellular connection - GPRS (IP), GSM and SMS. 
 
Option settings: 2 attempts; 4 attempts (default); 8 attempts; 12 attempts and 
16 attempts.