80 D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
First the panel siren sounds for 3 seconds after which the PowerMaster-10 /
PowerMaster-30 system will automatically repeat the procedure for the next siren
enrolled in the system until all sirens are tested. You should listen to the sirens
sounds and make sure that all sirens sound.
When all the sirens have been tested, the display reads . Press
the or the button to confirm the test.
Here the control panel reads the temperature of zone.
To display the temperature of zones on the control panel, press . The control
panel reads the temperature of the each zone. The display alternates between the
temperature, the sensor number and the sensor location, as in the following example:
changes to changes to
. Repeatedly click the button to review the temperature
of each zone (by Temperature Sensor).
When the temperature of all zones has been reviewed, the display reads
. Press the or the button to confirm the test and
then move to the next step to test the other devices.
Here you can test all devices in one procedure. [2]
While in , press to initiate the test.
The control panel now reads . "N" indicates the number of
enrolled devices in the control panel that have not been tested. This number
automatically drops one count for every tested device.
When the screen appears, walk throughout the site to test the
detectors / sensors or press any key of the selected handheld device to initiate the
test.
After a device has been activated, the control panel reads "Zxx IS ACTIVATE" and
the "N" indicator drops one count.
Pressing during the testing process will display details of each device that has
not yet been tested. The control panel reads the device number, followed by the
device type (for example, Contact Sensor, Motion Sensor or Keyfob) and followed by
the device location. At this stage, pressing any one of the following keys will open the
following options:
1. Press to view details of the next untested device. [3]
2. Press to exit the test process.
During testing, you can also check the signal strength indication of each device, (for
further details, refer to the device Installation Instructions).
After all devices have been tested, the control panel reads .
Here you can select a specific device you wish to test (Contact Sensors, Motion
Sensors, Glassbreak Sensors, Smoke Sensors, CO Sensors, Gas Sensors, Flood
Sensors, Wired sensors, Keyfobs or Keypads).
Press to enter the sub menu and use to scroll through
the device families. Press to enter the sub menu For
example: .
The following screens will appear:
Where Zxx indicates the device zone number.
If there is no device, the following screen will appear: .
NOT ACTIVE NNN
DEVICE TESTS END
NOT ACTIVE NNN
MOTION SENSORS
DEVICE TESTS END
Guest room
Z01:Temp. Sensor
Z01 24.5
°
SIREN TESTS END
TEMPERATURE TEST
TEST ALL DEV
ICES
TEST ONE DEVICE
CONTACT SENSORS
MOTION SENSORS
GLASSBREAK SENS.
TEST ONE DEVICE
< device family >
Zxx:<device name>
< location >
NO EXISTING DEV.
TEST ALL DEVICES