VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
The xxx’s represent values between 0 and 255 and the user should enter their own IP
address in this form. The configuration program will not accept anything outside this
format. Remember to separate each part of the address with a period (dot). For example:
NSH-5509# config terminal
NSH-5509(config)# ip 192.168.99.222
NSH-5509(config)# netmask 255.255.255.0
NSH-5509(config)# gateway 192.168.99.1
4. These system parameters are invalid until you save configuration with “write
memory” command. After you enter “write memory” command, the system will
auto restart immediately.
NSH-5509(config)# exit
NSH-5509# write memory
It takes a few moments to write memory...
NSH-5509# write memory $$$ Restart system....!!!
After the system restarts completely, you can type in “show ip” command to verify
system settings.
NSH-5509# show ip
[eth0] Network Configuration:
MAC Address : 00:0B:04:09:03:07
DHCP Client: Disabled
IP Address: 192.168.99.222
Netmask : 255.255.255.0
Gateway : 192.168.99.1
When the address has been changed, please make a note of the new address, and
keep it in a safe place. With HyperTerminal, the command lines are the same as that for
telnet.
Note: IP addresses are unique. If an address isn’t available, please contact the
appropriate authorities to apply for one.