LP-Gas System
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
WINDSOR
7•182
Tank Measurement - To measure level of a tank simply push button on dis-
play panel corresponding to tank you wish to measure. Lights on panel will turn
on in sequence indicating level of tank.
Calibration - The monitoring panel comes factory calibrated for accuracy
and should not need to be adjusted. If system does not read accurately recalibra-
tion may be necessary.
To recalibrate LP tank gauge proceed as follows:
Using adjustment tool, simultaneously push button for tank and rotate
adjustment point. Turn counterclockwise until the light indication is decreasing.
Gently rotate the adjustment back clockwise until the light indication is at full.
NOTE: Fill LP tank prior to calibration.
If you smell gas (a rotten egg or sulfur smell) at any time, perform the fol-
lowing steps immediately:
• Shut off gas appliances.
• Manually turn off the main gas supply at the tank.
• Do not attempt to operate any electric switch.
• Open windows and doors.
• Evacuate the motorhome.
• Keep open flames, spark producing devices and smoking material out
of the area.
• Contact a qualified service technician to find the source and repair
the gas leak.
WARNING: A fire or explosion from ignited gas or gas fumes
can seriously injure you or cause death.
MONITOR PANEL
MEASUREMENT
& CALIBRATION
CHECKLIST-
LP-GAS
EMERGENCY
PROCEDURES