Driving & Safety
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
2•62
The gas detector operates on 12 Volt DC, with a current draw less than
1/10th of one amp.
CAUTION: This detector will not alarm during the 3
minute warm up cycle.
Press the TEST switch any time during the warm up cycle or while in nor-
mal operation. The LED should flash RED and the alarm should sound. Release
the switch. This is the only way you should test the detector. The test feature
checks full operation of the detector.
WARNING: Test the operation of this detector after the
motorhome has been in storage, before each trip and at least
once per week during use.
The RED LED will flash and the alarm will sound whenever a dangerous
level of propane or methane gas is detected. The detector will continue to alarm
until the gas clears or the Test/Mute switch pressed.
Procedures To Take During An Alarm:
1. Turn off all gas appliances, (stove, heaters, furnace),
extinguish all flames and smoking material. Evacuate,
leave doors and windows open.
2. Turn off the propane tank valve.
3. Determine and repair the source of the leak. Seek professional help
if necessary.
CAUTION: Do Not re-enter until the problem is corrected.
Alarm Mute:
Press the Test-Mute button when the detector is in alarm.
1. The Red LED will continue flash and the alarm will beep
every 30 seconds, until the gas level has dropped.
2. The LED will flash Green until the end of the Mute cycle.
3. If dangerous gas levels return before the end of the mute cycle,
the alarm will beep 4 times and return to phase 1.
4. After 2 minutes the detector will return to normal operation
(solid Green) or resound the alarm if dangerous levels of gas
remain in the area.
WINDSOR
Testing
Alarm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Windsor Monaco and is the answer not in the manual?

Windsor Monaco Specifications

General IconGeneral
Fuel TypeGasoline
GPS NavigationOptional
WiFiOptional
Solar PanelOptional
ChassisFord
Sleeping Capacity4
HeatingForced-air furnace
Refrigerator2-way
Stove3-burner
MicrowaveYes
Audio SystemAM/FM/CD/DVD
ShowerYes
SinkYes
FlooringVinyl
SteeringPower steering
Seatbelts4
AirbagsDriver and passenger
BatteriesTwo house batteries
Air ConditioningRoof-mounted
FurnitureDinette, sofa
BluetoothOptional
Warranty1-year limited