WARNING: Do not attempt to adjust the regulator, it is preset
at the factory. If adjustments need to be made it requires spe-
cial equipment. Failure to follow these instructions may result
in a fire or explosion and cause severe personal injury or
death. DO NOT ATTEMPT TO REENTER THE
MOTORHOME UNTIL THE PROBLEM HAS BEEN COR-
RECTED!
Each gallon of LP-Gas produces approximately 92,000 BTU’s of heat. One 27
gallon tank produces two million BTU’s. Total consumption depends on the rate
of usage by each appliance and the operating time. The stove and heating systems
typically use the most gas. With sub-freezing temperatures and high winds, con-
sumption by the furnace can be very high. Check the tank level often in cold
weather.
WARNING: LP-Gas is highly volatile and extremely explosive.
Never use matches or open flame to test for leaks. Use only
approved LP-Gas leak testing solution to test for leaks. Unapproved
solutions can damage copper tubing and brass fittings. Never
attempt to adjust LP-Gas regulators without the use of proper
equipment. Improper LP-Gas regulator adjustment will affect the
performance of LP-Gas operated appliances. Incorrect flame or
explosion can occur. Only qualified personnel should perform any
maintenance or repair to the LP-Gas system.
A primary manifold black steel pipe running throughout the motorhome dis-
tributes LP-Gas to secondary lines. All secondary lines leading to gas appliances
are made of copper tubing with flared fittings. If any lines rupture do not attempt
to splice them. Always run a new line. We recommend gas distribution work be
performed by an authorized dealer or an authorized service technician. When
removing or servicing any gas appliance, manually close the main valve located
on the side of the LP-Gas tank. This will prevent dangerous gas leakage that
could result in an explosion and possible serious injury. If you suspect a gas leak
get the system inspected and repaired by a qualified service technician as soon as
possible.
LP-Gas System
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
WINDSOR 7•185
LP-GAS
CONSUMPTION
LP-GAS
DISTRIBUTION
LINES