• Allow the batteries to cool for approximately three hours. Check
the electrolyte solution with a hydrometer. Avoid overcharging
the battery resulting in damage to the healthy cells.
• Add distilled water if necessary. Install battery caps. Use large
quantities of fresh water to rinse the entire battery compartment
and surrounding area.
• Install fuses to solar panel charge leads.
• Observing polarity, hook the 12 Volt DC supply leads to the back
of the refrigerator. Do not reverse polarity. Damage to the refrig-
erator circuit board can result.
• Hook up the battery maintainer. Be sure the wires are connected
to the correct location.
CAUTION: Never equalize charge a frozen battery.
WARNING: Liquid lead acid batteries produce highly explosive
hydrogen gas when being charged. Extinguish all flames and other
sources of ignition. Never smoke around batteries. Danger of
explosion, fire, property damage, serious personal injury or death
can result!
The remote is used to program or turn on or off the inverter. The RC7 GS
remote is a display only. All the programming information is retained in the
inverter. If the inverter exhibits unusual symptoms or behavior, such as not
responding to commands or displaying erroneous error conditions, “re-
booting” the inverter may alleviate these symptoms.
To re-boot the inverter:
1. Remove AC power from the inverter by disconnecting shore power
and/or shutting the generator off.
2. Turn the main switch on the inverter to the OFF position.
3. Switch house and chassis main battery disconnects to the OFF position.
4. Wait 30 seconds, this allows time for capacitors to discharge.
5. Switch house and chassis main battery disconnects to the ON position.
6. Turn the main switch on the inverter to the ON position.
7. Connect the shore power cord or start the generator.
The AC distribution panel is located in the bedroom. The main AC panel 120
Volt circuit breakers receive power from the transfer switch, which is powered
by either shore power or the on board generator. Power is introduced into the
panel to the 50 amp MAIN breaker first, followed by power being fed to the
individual branch circuit breakers. The panel label describes the breaker layout
and the item, outlet or appliance to which they pertain.
Electrical Systems - House
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
WINDSOR
8•206
Re-booting the
Inverter
DISTRIBUTION
PANEL -
HOUSE 110
AC Panel