• Turn off water heater when not in use to conserve LP-Gas.
• The water heater tank capacity is ten gallons. When running the shower,
conserve the heated water by shutting the shower water off when not in
immediate use.
• Use caution when adapted to 30 amp shore service. When the water heater
element is in operation it will use approximately 12 amps. Appliances
may need to be operated in sequence to avoid tripping a breaker.
• The temperature and pressure (T & P) safety relief valve on the outside
of the water heater is set to open at 210°F or 150 psi. When water
temperature and pressure reach these settings the valve may drip until
the pressure has dropped. Avoid opening the T & P valve manually as it
may continued to leak. The valves can be purchased from most hardware
stores.
WARNING: Before beginning any service or work on the
water heater make sure the LP-Gas is turned off, the 120
Volt AC source has been disconnected and the 12 Volt DC
source has been disconnected. Failure to do so can result in
explosion, fire or injury.
• If water heater fails to light check the outside burner tube for obstructions
Spiders may make nests in the burner tube.
• If the indicator light on the monitor panel does not light and the water
water heater does not light, make sure the battery cut-off switch at the
entry door is on, or check for a blown fuse in the house distribution
panel.
• If the switch at the galley is on but there is no hot water, check the
ON/OFF switch located outside behind the water heater inspection
panel.
• If the 120 Volt piloted switch does not light check the AC source,
breaker, shore cord connection or transfer switch.
The water heater is equipped with a temperature-pressure relief valve. The
water heater may discharge at the temperature-pressure relief valve during the
heating cycle, due to thermal expansion of water. The temperature-pressure
relief valve is designed to open if the water temperature within the heater
reaches 210°F (98.8°C), or if the water heater pressure reaches 150 psi. This
can be related to the fact the motorhome utilizes a closed system. When there
is a discharge, a normal occurrence, it should not be considered a faulty valve.
Troubleshooting -
LP-Gas Operations
Troubleshooting -
Electric Operations
Temperature-
Pressure
Relief Valve

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Windsor Monaco and is the answer not in the manual?

Windsor Monaco Specifications

General IconGeneral
Fuel TypeGasoline
GPS NavigationOptional
WiFiOptional
Solar PanelOptional
ChassisFord
Sleeping Capacity4
HeatingForced-air furnace
Refrigerator2-way
Stove3-burner
MicrowaveYes
Audio SystemAM/FM/CD/DVD
ShowerYes
SinkYes
FlooringVinyl
SteeringPower steering
Seatbelts4
AirbagsDriver and passenger
BatteriesTwo house batteries
Air ConditioningRoof-mounted
FurnitureDinette, sofa
BluetoothOptional
Warranty1-year limited