EasyManua.ls Logo

Windsor Monaco - Battery Specifications

Windsor Monaco
318 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50% state of charge would net viewing time for the television at approximately
13 hours in ideal conditions.
The run time figure will vary greatly with the actual state of charge of
the battery bank when the discharge process begins. Ambient temperature, com-
bined with other working loads such as lights and parasitic loads applied to bat-
teries, affect run times. Calculating the exact run time is not precise due to all
the variables and equations involved; however, an approximate time
figure can be obtained. Proper battery maintenance and charge cycles affect bat-
tery performance. Observe the battery condition with hydrometer and
voltage readings. Use only distilled water when filling batteries. To achieve the
highest quality of battery performance and longevity, keep batteries in their
proper operating range.
Electrical Systems - House
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
WINDSOR
8•220
**Battery connections are made in a Series/Parallel connection.
Domestic batteries are not rated in Cold Cranking Amps (CCA).
Battery Specifications
Ah
(20hr)
240
225
255
CCA
950
**
**
RC
(25A)min
.
450
447
25A - 461
15A - 801
8A - 1627
5A - 3130
Chassis
12 Volt Chassis
31P-MHD (2 each)
6 Volt Domestic
U2200 (4 each)
All Electric
Battery
Specifications
GPL-8D (5 each)
STATE OF
VS.
OPEN CIRCUIT
CHARGE VOLTAGE
100% 12.66v
75% 12.45v
50% 12.24v
25% 12.06v
Discharged 11.89v
STATE OF
VS
SPECIFIC
CHARGE GRAVITY
100% 1.265
75% 1.225
50% 1.190
25% 1.155
Discharged 1.120

Table of Contents