Electrical Systems - Chassis
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
WINDSOR 9•229
STATE OF
VS.
OPEN CIRCUIT
CHARGE VOLTAGE
100% 12.66v
75% 12.45v
50% 12.24v
25% 12.06v
Discharged 11.89v
STATE OF
VS
SPECIFIC
CHARGE GRAVITY
100% 1.265
75% 1.225
50% 1.190
25% 1.155
Discharged 1.120
CUMMINS ENGINE COLD CRANKING AMPS REQUIREMENTS
ISB 1100 CCA 12 VOLTS
* ISC 1250 CCA 12 VOLTS
ISM 1800 CCA 12 VOLTS
N14 1800 CCA 12 VOLTS
CCA Rating are at 0º F. These
are the minimum requirements.
Battery connections are made in a Series/Parallel connection.
Domestic batteries not rated in Cold Cranking Amps (CCA).
Chassis
12 Volt Chassis
8D-MHD (1)
6 Volt Domestic
U2200 (4 each)
Ah
(20hr)
240
225
CCA
1400
**
RC
(25A)
minutes
450
447
Battery Specifications - Chassis