WARNING: This panel contains high voltage which can
cause serious injury or death. Before beginning any work
or testing procedures involving the electric panels, or any
of the branch circuits, be sure the motorhome is
unplugged from shore power, the generator is not running
and the inverter is in the OFF position. Certain testing
procedures can require the AC power to be on. Only qual-
ified personnel or personnel with electrical backgrounds
should attempt any testing procedures.
Branch circuit breakers supply AC power to the different items or
“loads.” An electrical load is any item or device that will use current when
supplied with an electromotive force. Should a breaker “trip” from over
current use, or a short circuit condition, the load to which the breaker is
suppling the electromotive force should be reviewed or disconnected to
determine the cause of the trip. If no cause is found, or not readily apparent,
reset the breaker by toggling the breaker to the OFF position, then back to
ON. Should the breaker trip again after the load is reapplied it may indicate a
fault with that particular load. Do not continue to reset breaker until the
problem has been corrected diagnosed and corrected.
Electrical Systems - House
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
WINDSOR 8•207