8 If there is no oil flow from none of the leakage pipes, find (if applicable) the connecting
pipe that has a leakage as follows:
8.1 Carefully loosen the screw plug of the inspection point of the first connecting
pipe a maximum of two turns.
8.2 Do a check for oil flow.
8.3 If there is an oil flow, shut-off the related connecting pipe an repair it at the next
occasion, refer to the Maintenance Manual.
8.4 Tighten the screw plug.
8.5 Do Step 8.1 to Step 8.4 again for the other connecting pipe.
CLOSE UP
None
X92DF
AA00-0000-00AAA-311A-A
Operation Manual Examine the supply unit for servo oil leakage
Winterthur Gas & Diesel Ltd.
- 534 - Issue 002 2020-08