Decommissioning
3066501_201910 WOLF GmbH | 69
9 Decommissioning
NOTE
Improper shutdown!
Pump damaged due to downtime.
Heating system damaged due to frost.
The heat generator may only be operated using the control module.
9.1 Taking the heat generator out of service temporarily
BM-2 programming unit operating instructions for users
AM display module operating instructions for users
Activate standby mode using the control module.
9.2 Putting the heat generator back into service
Activate a heating mode using the control module.
9.3 Taking the heat generator out of service in an emergency
Fig. 9.1 ON/OFF switch
Switch OFF the heat generator at the ON/OFF switch.
Notify a contractor.
9.4 Taking the heat generator out of service permanently
Prepare for decommissioning
DANGER
Risk of electrical voltage even when the ON/OFF switch is set to OFF!
Danger of death from electrocution
Isolate the entire system from the power supply.
Switch OFF the heat generator at the ON/OFF switch.
Isolate the system from the power supply.
Safeguard the system against reconnection.
Disconnect the heat generator from the power.