Analog Programming Mode
M370046-01 4-17
4
Resistive-Controlled Current APG Setup
To activate APG current mode using an external resistor source:
1. Turn the mode control knob to the CAP position to press the Rotary
knob/Enter button if the control knob is already at CAP position.
CAPr is displayed on the output voltage display.
2. Turn Rotary knob/Enter button to select Rn1S (voltage source from
non-isolated connector).
3. Press the rotary knob/Enter button to commit the selected mode.
LE C is displayed on the output voltage display.
4. Once the desired level has been selected, press the Rotary knob/Enter
button to commit the change.
The display will return to the normal display.
Deactivating APG Current Mode
To deactivate the APG current mode:
1. Turn the mode control knob to the CAP position or press the Rotary
knob/Enter button if the control knob is already at the CAP position.
2. CAPr is displayed on the output voltage display.
3. Turn the Rotary knob/Enter button to select nonE.
4. Press the rotary knob/Enter button to commit the change.
The display will return to the normal display.