1.6 F: Option Settings
132 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
Setting 0: Disabled, Auto Reset not Possible
Setting 1: Enabled, Auto Reset Possible
■
F6-30: PROFIBUS Node Address
Sets the node address of a PROFIBUS-DP option card if installed.
■ F6-31: PROFIBUS Clear Mode Selection
Determines the operation when a “Clear Mode” command is received.
Setting 0: Reset
Resets the drive operation (frequency reference, inputs, outputs etc.).
Setting 1: Maintain the Previous State
Keeps the drive status the same as what it was before the Clear Mode command was
received.
■ F6-32: PROFIBUS Data Format Selection
Selects the data format used for Profibus communication.
Setting 0: PPO Type Data Format
Setting 1: Conventional Data Format
■
F6-35: CANopen Node ID Selection
Selects the node ID of a CANopen option board if installed.
No. Parameter Name Setting Range Default
F6-30 PROFIBUS Node Address 0 to 125 0
No. Parameter Name Setting Range Default
F6-31 PROFIBUS Clear Mode Selection 0 or 1 0
No. Parameter Name Setting Range Default
F6-32 PROFIBUS Data Format Selection 0 or 1 0
No. Parameter Name Setting Range Default
F6-35 CANopen Node ID Selection 0 to 127 99