A.2 Parameter Table
336 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
H3-11
<22>
Terminal A2 Gain
Setting
Sets the level of the input value selected in H3-
10 when 10 V (20 mA) is input at terminal A2.
-999.9 to
1000.0
100.0
%
AAA 419 177
H3-12
<22>
Terminal A2 Input
Bias
Sets the level of the input value selected in H3-
10 when 0 V (0 or 4 mA) is input at terminal
A2.
-999.9 to
999.-
0.0% A A A 41A 177
H3-13
Analog Input Filter
Time Constant
Sets the primary delay filter time constant for
terminals A1 and A2. Used for noise filtering.
0.00 to
2.00
0.03
s
AAA41B 177
<22> Parameter can be changed during run.
<40> The availability of certain parameters depends on the control method used.
H3 Multi-Function Analog Input Settings
H3-
Setting
Function Maximum Input Level Possible
Control
Mode
Pg.
V/f
OL
V
PM
0 Frequency Bias
Max output frequency (E1-04).
Same value can be set using H3-02 and H3-10.
OOO178
1 Frequency Gain 10V = 100% O O O 178
2
Auxiliary Frequency Reference
(used as a Multi-Step Speed 2)
Maximum output frequency (E1-04) O O O 178
4 Output Voltage Bias Motor rated voltage (E1-05). O – − 178
7
Overtorque/Undertorque Detection
Level
Open Loop Vector: Motor rated torque
V/f Control: Drive rated current
OOO178
B PID Feedback 10V = 100% O O O 179
C PID Set Point 10V = 100% O O O 179
E Motor Temperature (PTC input) 10 V = 100.00% O O O 179
F Not used / Through mode – O O O 179
10 FWD Torque Limit Motor rated torque − O − 179
11 REV Torque Limit Motor rated torque − O − 179
12 Regenerative Torque Limit Motor rated torque − O − 179
15 FWD/REV Torque Limit Motor rated torque − O − 179
16 Differential PID Feedback 10 V = 100% O O O 180
30/31 FBD’s Analog Input 1/2 Depending on function. O O O 180
No. Name Description Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
O
LV
P
M