9.2 List of Parameters
9.2.2 List of Parameters
9-11
Pn00C
2
Application Function
Selections C
0000h
to
0131h
0000h
After
restart
Setup
*1
Pn00D
2
Application Function
Selections D
0000h
to
1001h
0000h All
After
restart
Setup
*1
Pn00F
2
Application Function
Selections F
0000h
to
2011h
0000h All
After
restart
Setup
Pn010 2
Axis Address Selection
for UART/USB Commu-
nications
0000h
to
007Fh
0001h All
After
restart
Setup
Pn021 2
Reserved parameter (Do
not change.)
0000h All
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Function Selection for Test without a Motor
Applicable
Motors
0 Disable tests without a motor.
All
1 Enable tests without a motor.
n.
X
Encoder Resolution for Tests without a Motor
Applicable
Motors
0 Use 13 bits.
Rotary
1 Use 20 bits.
2 Use 22 bits.
3 Use 24 bits.
n.X
Encoder Type Selection for Tests without a Motor
Applicable
Motors
0 Use an incremental encoder.
All
1 Use an absolute encoder.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
Overtravel Warning Detection Selection
0 Do not detect overtravel warnings.
1 Detect overtravel warnings.
n.X
Preventative Maintenance Warning Selection Reference
0 Do not detect preventative maintenance warnings.
*1
1 Detect preventative maintenance warnings.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)

Table of Contents