SERVO SELECTION AND DATA SHEETS
5.4.2 Servomotor Dimensional Drawings cont.
296
Type SGM- L LL LM QK U W T Screw
diminsions
Out-
put
W
(HP)
Approx.
mass
kg
(lb)
Allow-
able
radial
load
N (lb)
Allow-
able
thrust
load
N (lb)
02V312B
166.0
(6 )
136.0
(3)
62.5
(2 6)
No key
200
(0 2 )
1.6
(3 3)
245
(
1
)
74
(16
6
)
02W312B
(6.54) (5.35) (2.46)
y
(0.27) (3.53) (55 .1) (16.6)
02V314B
20
(0 9)
3
(0 12)
5
(0 20)
5
(0 20)
02W314B
(0.79) (0.12) (0.20) (0.20)
02V316B
M5, depth 8
02W316B
,
p
(0.31)
03W312B
194.0
(6)
164.0
(6 6)
90.5
(3 6)
No key
300
(0 0)
2.2
(8)
03W314B
(7.64) (6.46) (3.56)
20
(0 9)
3
(0 12)
5
(0 20)
5
(0 20)
(0.40) (4.85)
03W316B
(0.79) (0.12) (0.20) (0.20)
M5, depth 8
(0.31)
04V312B No key
400
(0 3)
04V314B
20
(0 9)
3
(0 12)
5
(0 20)
5
(0 20)
(0.53)
04V316B
(0.79) (0.12) (0.20) (0.20)
M5, depth 8
(0.31)
Note 1) The detector uses an incremental encoder 2048 P/R.
2) Type “V” indicates 200 V specification, and type “W” indicates 100 V specification.
3) “02V(W)314B”, “02V(W)316B”, “03W314B”, “03W316B”, “04V314B” and “04V316B”
have a keyed shaft. The keyway complies with JIS B 1301-1976 (precision). A straight
key is supplied.
4) The quoted allowable radial load is the value at a position 25 mm (0.98 in.) from the mo-
tor mounting surface.
5) The electromagnetic brake is only to hold the load in position and cannot be used to stop
the motor.
5

Table of Contents

Related product manuals