SERVO SELECTION AND DATA SHEETS
5.6.1 Cable Specifications and Peripheral Devices cont.
350
SFor 200VAC Class
Servopack Type
DR2-
Applicable
Servomotor
Power supply
capacity per
*
MCCB or
fuse
*
Noise filter
type
Recommended
noise filter
*3
Power
ON/OFF
Servopack
kVA
capacity
A
(reference
diagram)
Type Spec.
Switch
30 W
(0.04HP)
A3AC SGM−A3A j
SGM−A3V j
0.25
5
Applicable
LF−205A Single−phase
200 VAC
Contactor
35A or
50 W
(0.07HP)
A5AC SGM−A5A j
SGM−A5V j
0.3
,
100 W
(0.13HP)
01AC SGM−01A j
SGM−01V j
0.5
01ACP
SGMP−01A j
SGMP−01V j
200 W
(0.27HP)
02AC SGM−02A j
SGM−02V j
0.75
02ACP
SGMP−02A j
SGMP−02V j
400 W
(0.53HP)
04AC SGM−04A j
SGM−04V j
1.2 9 LF- 210 Single-phase
200 VAC
04ACP
SGMP−04A j
SGMP−04V j
,
750 W
(1.01HP)
08AC SGM−08A j
SGM−08V j
2.2 16
Not
applicable
LF- 220 Single-phase
200 VAC
Class, 20 A
08ACP
SGMP−08A j
SGMP−08V j
Note For power ON/OFF switch, use contactor 30A or above.
*1 Value at rated load.
*2 Braking characteristics (at 25_ C): 200% for 2s min., 700% for 0.01s min.
*3 Yaskawa recommends noise filters manufactured by Tokin Corp.
Yaskawa Controls Co., Ltd. can supply these noise filters.
5