5.6 Specifications and Dimensional Drawings of Peripheral Devices
351
SFor 100VAC Class
Servopack Type
DR2-
Applicable
Servomotor
Power supply
capacity per
Servopack
*
1
MCCB or
fuse
capacity
*
2
Noise filter
type
(reference
Recommended noise
filter
*3
Power
ON/OFF
switch
Servopack
*
1
kVA
capacity
*
2
A
(reference
diagram)
Type Spec.
switch
30 W
(0 04HP)
A3BC
SGMA3B j
0.25 5 Applicable LF- 205A Single-phase
200
V
AC
Contactor
35A
(0.04HP)
SGMA3W j
pp
gp
200 VAC
Class,
5
A
35A or
above
50 W
(0 07HP)
A5BC
SGMA5B j
0.3
Class
,
5
A
above
(0.07HP)
SGMA5W j
100 W
(0.13HP)
01BC
SGM01B j
SGM01W j
0.5
Not
a
pp
licable
01BCP
SGMP01B j
SGMP01W j
applicable
200 W
(0.27HP)
02BC
SGM02B j
SGM02W j
0.75 8 LF- 210 Single-phase
200 VAC
Class
10
A
02BCP
SGMP02B j
SGMP02W j
Class
,
10
A
300 W
(0.40HP)
03BC
SGM03B j
SGM03W j
1.4 15 LF- 220 Single-phase
200 VAC
Class
20
A
03BCP
SGMP03B j
SGMP03W j
Class
,
20
A
Note For power ON/OFF switch, use contactor 30A or above.
*1 Value at rated load.
*2 Braking characteristics (at 25_C): 200% for 2s min., 700% for 0.01s min.
*3 Yaskawa recommends noise filters manufactured by Tokin Corp.
Yaskawa Controls Co., Ltd. can supply these noise filters.
The types of cable are shown in the table below. Use it in combination with the table
above.
Cable Type
Conductor Allowable Temperature
C
Symbol Name
p
_C
PVC Normal vinyl cable ---
IV 600 V vinyl cable 60
HIV Temperature-resistant vinyl cable 75
Note 1) Use cable with 600 V min. withstand voltage for main circuits.
2) Consider allowable current reduction ratio if cables are bundled in PVC or metal ducts.
3) Use temperature-resistant cable under high ambient or panel temperature where nor-
mal vinyl cables rapidly deteriorate.
5