LIST OF USER CONSTANTS
476
User
Constant
No.
Bit
No.
Setting Factory
Setting
Error counter
l
il
Cn-02 A
0 1
0
clear signal
Clears the error counter when an error
counter clear signal is at high level.
Clears the error counter
when the leading edge of an
error counter clear signal
rises.
Selection of
speed/torque
B
0 1
0
See note 4
speed/torque
or position
control mode
Not used. Position control mode
See
note
4
Torque
reference
C
0 1
0
re
f
erence
filter
Primary Secondary
Reference
l
li
D
0 1
0
pulse logic
Does not invert reference pulse logic. Inverts reference pulse
logic.
Position
i
E
0 1
0
error monitor
level
Displays position error Un-08 in x 1
reference units while in monitor mode.
Displays position error
Un-08 in x 100 reference
units while in monitor mode.
Reference
l
fil
F
0 1
0
pulse filter
Line driver
(Maximum reference pulse frequency: 450
kpps)
Open collector
(Maximum reference pulse
frequency: 200 kpps)
: User constants that must be always set
Note 1) Internal speed selection is valid only when bit 2 of Cn-02 is set to ā€œ1.ā€
2) The factory setting depends on the Servopack type as shown below.
Servopack Type Factory Setting
DR2-j
0
DR2-jP
1
3) At full-closed loop specification, when Cn-01 bit 4 is set to 1, external PG phase-C dis-
connection error is not detected.
4) At full-closed loop specification, factory setting of Cn-02 bit B is 1.
NOTE For the Cn-01 and Cn-02 memory switches, always turn the power OFF and then ON after
changing the setting. This makes the new setting valid.