11.2 List of Parameters
11-9
11
Appendix
11.2.2 Parameters
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Pn000
Basic Function Select Switch 0 0000 to 00B3 0000 After restart Setup
0
1
2 to 3
Forward reference for forward rotation.
Forward reference for reverse rotation. (Reverse rotation mode)
Reserved (Do not use.)
Direction Selection (Refer to 5.2.2.)
0
1
2
3
4
5
6
7
8
9
A
B
Speed control (analog reference)
Position control (pulse train reference)
Torque control (analog reference)
Internal set speed control (contact reference)
Internal set speed control (contact reference)
Speed control (analog reference)
Internal set speed control (contact reference)
Position control (pulse train reference)
Internal set speed control (contact reference)
Torque control (analog reference)
Position control (pulse train reference)
Speed control (analog reference)
Position control (pulse train reference)
Torque control (analog reference)
Torque control (analog reference)
Speed control (analog reference)
Speed control (analog reference)
Speed control with zero clamp function
Position control (pulse train reference)
Speed control with inhibit function
Control Method Selection (Refer to 5.7.)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Reserved (Do not change.)
Reserved (Do not change.)
(Refer to 5.2.2)
(Refer to 5.7)