2 Panel Operator
2.6.1 Parameter Setting Mode for Parameter Setting Type
2-8
(2) Parameters with Setting Ranges of Six Digits or More
Panel operator displays five digits. When the parameters have more than six digits, values are displayed and
set as shown below.
Procedures for setting of "Pn522 = 0123456789" are shown below.
Step
Display after
Operation
Keys Description
1
Press the MODE/SET Key to select the parameter setting
mode (Pn). If Pn522 is not displayed, press the UP
Key or the DOWN Key to select Pn522.
2
Press the DATA/SHIFT Key for approximately one sec-
ond. The current data for bottom four digits of Pn522 are
displayed. (In this case, "0007" is displayed.)
Press the DATA/SHIFT Key to move to other digits, and
change the value by pressing the UP/DOWN Key. (In this
case, "6789" is set.)
3
Press the DATA/SHIFT Key for approximately one sec-
ond. The current data for middle four digits are displayed.
(In this case, "0000" is displayed.)
Press the DATA/SHIFT Key to move to other digits, and
change the value by pressing the UP/DOWN Key. (In this
case, "2345" is set.)
4
Press the DATA/SHIFT Key for approximately one sec-
ond. The current data for top two digits are displayed. (In
this case, "00" is displayed.)
Press the DATA/SHIFT Key to move to other digit, and
change the value by pressing the UP/DOWN Key. (In this
case, "01" is set.)
The value "0123456789" is set.