(3) Wiring Example with Single-phase 200 V Power Supply Input
Single-phase 200 V SERVOPACK SGDV-R70A, R90A, 1R6A, 2R8A, 5R5A
(4) Power Supply Capacities and Power Losses
The following table shows SERVOPACK’s power supply capacities and power losses when using single-
phase 200 V power supply.
Note 1. SGDV-R70A, R90A, 1R6A, and 2R8A SERVOPACKs do not have built-in regenerative resistors. If the regener-
ative energy exceeds the specified value, connect an external regenerative resistor.
2. Regenerative resistor power losses are allowable losses. Take the following action if this value is exceeded.
• Remove the lead from the internal regenerative resistor in the SERVOPACK. (SGDV-5R5A)
• Install an external regenerative resistor.
3. External regenerative resistors are options.
1PL
1SA
2SA
3SA
1D:
: Indicator lamp
: Surge absorber
: Surge absorber
: Surge absorber
Flywheel diode
1QF
1FIL
1KM
: Molded-case circuit breaker
: Noise filter
: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay
1KM
1Ry
1PL
1KM
2KM
1SA
1Ry1KM
2SA
L1
ENC
SERVOPACK
SGDV-A
U
V
W
M
0 V
1Ry
ALM+
ALM−
31
32
1D
2KM
L3
B2
B3
L2
CN1
1QF
RT
1FIL
+24 V
1
2
L1C
1KM
L2C
3SA
B1/
(For servo
alarm display)
supply ON
Servo power
supply OFF
Servo power
Main Power
Supply
Maximum
Applicable
Servomotor
Capacity
[kW]
SERVOPACK
Model
SGDV-
Power Supply
Capacity per
SERVOPACK
[kVA]
Output
Current
[Arms]
Main Circuit
Power Loss
[W]
Regenerative
Resistor
Power Loss
[W]
Control
Circuit
Power Loss
[W]
Total
Power
Loss
[W]
Single-phase
200 V
0.05 R70A 0.2 0.66 5.2
–
17
22.2
0.1 R90A 0.3 0.91 7.4 24.4
0.2 1R6A 0.7 1.6 13.7 30.7
0.4 2R8A 1.2 2.8 24.9 41.9
0.75 5R5A 1.9 5.5 52.7 8 77.7