Source
4-25
IM CA150E
1
2
3
4
5
6
7
8
9
10
11
12
App
4.9 Sweep Output Functions
Saving Source Values
1 Set the source value to output (FUNCTION, RANGE, Setting Value).
2 Press the SAVE key. (MEM No. appears.)
3 Use the ▲ ▼
key to select the memory number.
4 Press the ENTER key to conrm the selection.
(MEM No. disappears.)
Source value
Program Sweep
1 Press the SWEEP SET key three times to select Program Sweep.
Step Sweep → Linear Sweep → Program Sweep
(SWEEP and MEM NO. appear.)
2 Use the ▲ ▼
key to set the memory number (Start).
(The source value that corresponds to a memory number is displayed)
3 Press the SOURCE ON/OFF key to start output automatically.
(Output moves back and forth from the start to the last memory number.)
4 Press the SOURCE ON/OFF key again to stop the output.
5 Press the SWEEP SET to cancel the sweep output function.
→ Cancel
If you press the SOURCE ON/OFF key again after output is stopped in
Step 4 above, output resumes from the stopped step.
If you change the starting number while output is stopped and
the press the ON/OFF key again, output restarts from the rst step.