6.5 Wiegand Setup
In the initial interface, press
> Comm. > Wiegand Setup to enter the Wiegand Setup setting
interface.
6.5.1 Wiegand Input
Wiegand Input connector supports card reader, or connects the device as a master device to another
device (slave device), forming a master/slave system.
Select Wiegadn Inputand
press
to enter
Set parameters in Wiegand Inputinterface
Wiegand Format: User can choose among the following built-in Wiegand formats: Wiegand 26,
Wiegand 26a, Wiegand 34, Wiegand 34a, Wiegand 36, Wiegand 36a, Wiegand 37, Wiegand 37a and
Wiegand 50.
Pulse Width (us):
The width of pulse sent by Wiegand card reader. The default value is 100 microseconds,
which can be adjusted within the range of 20 to 100 microseconds.
Pulse Interval (us): The default value is 1000 microseconds, which can be adjusted within the range of 200
to 20000 microseconds.
ID Type: Input content included in Wiegand input signal. User ID or Badge Number can be chosen.