523D SYSTEMS, INC. PN:80-D27 Rev.B
Setting menu
The Setting menu gives access to 2 sub-menus: Conguration and Event browser.
Conguration
The Conguration tool includes different parameters grouped in 8 tabs. Only the followings tabs are unlocked, the access
to other tabs require higher user level.
For each tab, the read-only value values are displayed in grey, the editable one in black with the blue border. To change the
settings, proceed as follow:
1. Click on the value.
2. Select/enter the new setting.
3. After modication, the new value is shown in red. Click on
to save the modications, or to cancel.
4. Some modications require the software control to be restarted. Refer to the
section "Closing / opening PX Control application" on page 66.
• General tab
This tab summarizes several basic
parameters associated to the machine:
• Language: select the language
of the sofwtare (English/French)
• Machine: specify the type of
printer (ProX DMP300, 200 or
100)
• Serial number: indicate the
serial number indicated on the
name plate of the printer
• Piston reducer: is the printer equipped with special piston reducer? (Yes/No)
• Oxygen tab
This tab indicates the settings related to the oxygen value on the manufacturing chamber:
• General safety O2 threshold: this setting value is an absolute percentage of oxygen. The manufacturing will stop
immediately if the oxygen value is upper than this setting. The recycling cycle and the powder vacuum are disabled.
If the setting is null, this function is disabled.
• Minimum O2 threshold to launch a manufacturing: it denes the minimum value of oxygen to produce. If O2
value is upper the setting, starting a job is not permitted for Operator level and is permitted for other levels (a
warning message will be displayed in such case).
• Manufacturing stop threshold: this setting value is a percentage relative to the oxygen set point. The
manufacturing will stop at the end of the layer if the oxygen value is upper than this setting. If the setting is null,
this function is disabled.