813D SYSTEMS, INC. PN:80-D27 Rev.B
Front and Back casings cleaning
Part required :
Vacuum cleaner equipped with wet separator and be explosion proof.
Natural ber brush
Damp cotton cloth
Caution: Personal Protective Equipment (PPE) must be used to protect the user against health or
safety risks during working tasks. Wear disposable rubber gloves, anti-static coverall, anti-static safety
shoes and safety glass. Wear disposable dust mask rated FFP3 or N99 level protection at minimum ; we
recommand the use of powered air purifying respirator.
The steps from 1 to 13 are performed to clean the front casings.
1. Move the feeding piston and the sintering piston to the position 200mm.
2. Switch off the printer (see section "Shutting printer down" on page 66).
3. Switch the locking key to position “0”, remove the key and keep it with you. This will prevent any power up of the printer
during the maintenance.
4. Remove the protective guard (1) and open the bottom access doors (2).
5. Remove the 3 cover panels.
WARNING: FIRE AND EXPLOSION HAZARDS.
COMBUSTIBLE DUST INSIDE. METAL POWDERS ARE FLAMMABLE AND POTENTIALLY EXPLOSIVE,
ESPECIALLY WHEN DISPERSED IN A CLOUD AND EXPOSED TO AN IGNITION SOURCE SUCH AS HEAT OR
STATIC ELECTRICITY SPARK. OPERATORS AND SERVICE PERSONAL SHOULD AVOID DISTURBING POWDER
MANIPULATE CAREFULLY TO AVOID AS MUCH AS POSSIBLE SUSPENDING OF FINE PARTICLES).
1
2
Panels to be removed

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3D Systems ProX DMP 300 and is the answer not in the manual?

3D Systems ProX DMP 300 Specifications

General IconGeneral
Brand3D Systems
ModelProX DMP 300
Category3D Printers
LanguageEnglish

Related product manuals