Installation
31
Use a shielded Ethernet cable (STP cable, Shielded Twisted Pair cable) to connect the
OpenCom 100 to a Local Area Network (LAN).
Do not allow any fluid to penetrate the OpenCom 100, because this may cause
electric shocks or short circuits.
Do not install the OpenCom 100 during a storm. Do not connect or disconnect lines
during a storm.
The OpenCom 100 is designed for indoor use only. Lay the cables so that they cannot
be walked on or tripped over.
The connection of external devices to the sensor/actor should be performed by a
qualified electrician.
Declarations of Conformity
The OpenCom 130, OpenCom 131 and OpenCom 150 ITC systems conform to the
requirements set down in the EU directive 99/5/EC. The Declaration of Conformity can
be viewed at the Aastra Web site at http://www.aastra.de or http://www.aastra.com.
Mounting Location
The ambient temperature for operating the OpenCom 100 must be between +5 and
+40°C. The power supply must be 230 V/50 Hz AC. A separate fuse for the power
supply is recommended.
To maintain the prescribed ambient temperature, mount the OpenCom 100 in a well-
ventilated location, away from direct sources of heat.
Do not position the OpenCom 100
• in front of or above heat sources such as radiators,
• in direct sunlight,
• behind curtains,
• in small, unventilated, damp rooms,
• on or near inflammable materials,
• or near high-frequency devices such as transmitters, X-ray or similar apparatus.
Use a separate 230 V power circuit and install overvoltage protection.