Program Interface Library AR_GET_RAW_MODE
CEI-100/CEI-200/CEI-x20 User’s Manual 89
AR_GET_RAW_MODE
CEI_INT16 ar_get_raw_mode (CEI_INT16 board, CEI_INT16 direction,
CEI_INT16 channel);
This function is used to inquire about the parity enable status of a
channel.
AR_ON if raw-mode is on (parity is disabled), AR_OFF if raw-mode is off
(parity is enabled).
board (input) board number.
direction (input) channel type: ARU_XMIT or ARU_RECV
channel (input) channel number.
Syntax
Description
Return Value
Arguments