Program Interface Library AR_NUM_XCHANS
CEI-100/CEI-200/CEI-x20 User’s Manual 119
AR_NUM_XCHANS
CEI_INT16 ar_num_xchans (CEI_INT16 board)
This function returns the number of transmitter channels that are
implemented on the specified board. This function is present only in the
CEI-x20 API; the CEI-100/200 boards do not support this function.
ARS_INVBOARD Board number out of range
ARS_BRDNOTLOAD Board has not been initialized.
ARS_BOARD_MUTEX Failed to acquire/release the board lock.
If no error was detected, this function returns the number of transmitter
channels implemented on the specified board.
board (input) board number.
Syntax
Description
Return Value
Arguments