Installation Configuring the CEI-420 and CEI-420A
CEI-100/CEI-200/CEI-x20 User’s Manual 28
For configurations with ARINC 573/717 capability, pin connections are
made as follows:
Table 21. CEI-420/420A P3 Pin Connections
ARINC 573/717 HBP transmit data +
ARINC 573/717 HBP transmit data -
ARINC 573/717 BPRZ transmit data +
ARINC 573/717 BPRZ transmit data -
ARINC 573/717 receive data +
(Either BPRZ or HBP)
ARINC 573/717 receive data -
(Either BPRZ or HBP)
Board Edge
Figure 14. CEI-420/420A P4 Front View
Table 22. CEI-420/420A P4 Pin Connections
For external wrap, connect each discrete output to the corresponding
discrete input. Use AMP connector p/n 102387-4 with contacts 1-
87309-4.