Program Interface Library AR_INIT_SLAVE
CEI-100/CEI-200/CEI-x20 User’s Manual 106
AR_INIT_SLAVE
CEI_INT16 ar_init_slave (CEI_INT16 board);
This routine first calls AR_RESET. It then initializes all of the ARINC
transmitter and receiver queue head and tail pointers. It has the side effect
of flushing out the data buffers. If you are using scheduled transmission
mode, this routine does not modify your message setup.
ARS_NORMAL The interface was properly initialized.
ARS_INVBOARD A board number out of the maximum
range was specified.
ARS_BRDNOTLOAD The requested board was not loaded first
with a call to AR_LOADSLV.
ARS_BOARD_MUTEX Failed to acquire/release the board lock.
board (input) board number of interest.
Syntax
Description
Return Value