Program Interface Library AR_SET_RAW_MODE
CEI-100/CEI-200/CEI-x20 User’s Manual 141
AR_SET_RAW_MODE
CEI_INT16 ar_set_raw_mode (CEI_INT16 board, CEI_INT16 direction,
CEI_INT16 channel, CEI_INT16 control);
Each transmit and receive channel can be configured to run in raw
mode. In this mode, parity isn’t used, and each 32-bit ARINC word is
transmitted or received with the parity (32nd) bit unchanged. This is
different from standard ARINC 429 data transfers, which call for the parity
to be calculated. Raw mode is typically used for some older ARINC
specifications such as ARINC 575. This routine is supported only on the
CEI-200 and the CEI-x20.
See AR_SETCHPARMS for a superior replacement function.
ARS_NORMAL Operation completed successfully.
ARS_INVBOARD Board is either not initialized or not
supported for requested mode.
ARS_BRDNOTLOAD Board not initialized.
ARS_INVARG Invalid argument value.
ARS_BOARD_MUTEX Failed to acquire/release the board lock.
board (input) board number
direction (input) type of channel specified in the channel
argument (transmit or receive). Valid values are:
ARU_XMIT transmit channel.
ARU_RECV receive channel.
channel (input) channel number. Valid arguments depend
upon the number of channels configured on the
board purchased. The first channel (transmit or
receive) is number 0
control (input) enables or disables raw mode. Valid values
are:
AR_ON enable raw mode on this channel.
AR_OFF disable raw mode on this channel.
Syntax
Description
Return Value
Arguments