Program Interface Library AR_GET_RX_COUNT
CEI-100/CEI-200/CEI-x20 User’s Manual 90
AR_GET_RX_COUNT
CEI_UINT32 ar_get_rx_count (CEI_INT16 board, CEI_INT16 channel);
The software maintains a count of the number of ARINC data words
received over the interface for each channel since the interface was
initialized or since the count was reset (see AR _CLOSE). This routine
returns that number.
On the CEI-100 only, the returned value is 32 bits, but the data has only
16-bit accuracy. The most significant 16 bits are not used.
Count of ARINC data words.
board (input) board number.
channel (input) receive-channel number.
Syntax
Description
Note:
Return Value
Arguments