CEI-x20 Structure Definitions Structures
CEI-100/CEI-200/CEI-x20 User’s Manual 173
If this call is for ARU_RECEIVER, the value is
0xPPNN, where PP is the receiver positive threshold
value and NN is the receiver negative threshold. On
the CEI-820, the negative receiver threshold is
ignored and automatically set to the additive inverse
of PP (that is, NN = -PP).
If specified as 0x0000 the DAC voltages are not
modified. In either case, multiple channels might be
sharing the associated DAC and will all be affected
by the change in the DAC value(s) supplied by this
argument.
Reserved2 Reserved for future error injection use.