138 Parameters
Magnetized Bit 1 of 06.17 Drive status word 2 (see page 112). 6
Running Bit 6 of 06.16 Drive status word 1 (see page 112). 7
Ready ref Bit 2 of 06.11 Main status word (see page 111 ). 8
At setpoint Bit 8 of 06.11 Main status word (see page 111 ). 9
Reverse Bit 2 of 06.19 Speed control status word (see page 113). 10
Zero speed Bit 0 of 06.19 Speed control status word (see page 113). 11
Above limit Bit 10 of 06.17 Drive status word 2 (see page 112). 12
Warning Bit 7 of 06.11 Main status word (see page 111). 13
Fault Bit 3 of 06.11 Main status word (see page 111). 14
Fault (-1) Inverted bit 3 of 06.11 Main status word (see page 111 ). 15
Fault/Warning Bit 3 of 06.11 Main status word OR bit 7 of 06.11 Main status
word (see page 111).
16
Overcurrent Fault 2310 Overcurrent has occurred. 17
Overvoltage Fault 3210 DC link overvoltage has occurred. 18
Drive temp Fault 2381 IGBT overload or 4110 Control board temperature
or 4210 IGBT overtemperature or 4290 Cooling or 42F1 IGBT
temperature or 4310 Excess temperature or 4380 Excess
temperature difference has occurred.
19
Undervoltage Fault 3220 DC link undervoltage has occurred. 20
Motor temp Fault 4981 External temperature 1 or 4982 External
temperature 2 has occurred.
21
Reserved 22
Ext2 active Bit 11 of 06.16 Drive status word 1 (see page 112). 23
Remote control Bit 9 of 06.11 Main status word (see page 111 ). 24
Reserved 25…26
Timed function 1 Bit 0 of 34.01 Timed functions status (see page 191). 27
Timed function 2 Bit 1 of 34.01 Timed functions status (see page 191). 28
Timed function 3 Bit 2 of 34.01 Timed functions status (see page 191). 29
Reserved 30…32
Supervision 1 Bit 0 of 32.01 Supervision status (see page 184). 33
Supervision 2 Bit 1 of 32.01 Supervision status (see page 184). 34
Supervision 3 Bit 2 of 32.01 Supervision status (see page
184). 35
Start delay Bit 13 of 06.17 Drive status word 2 (see page 112). 39
RO/DIO control
word bit0
Bit 0 of 10.99 RO/DIO control word (see page 122). 40
RO/DIO control
word bit1
Bit 1 of 10.99 RO/DIO control word (see page 122). 41
RO/DIO control
word bit2
Bit 2 of 10.99 RO/DIO control word (see page 122). 42
PFC1 Bit 0 of 76.01 PFC status (see page 256). 45
PFC2 Bit 1 of 76.01 PFC status (see page 256). 46
PFC3 Bit 2 of 76.01 PFC status (see page 256). 47
PFC4 Bit 3 of 76.01 PFC status (see page 256). 48
PFC5 Bit 4 of 76.01 PFC status (see page 256). 49