Parameters 161
DI1 Digital input DI1 (10.02 DI delayed status, bit 0). 2
DI2 Digital input DI2 (10.02 DI delayed status, bit 1). 3
DI3 Digital input DI3 (10.02 DI delayed status, bit 2). 4
DI4 Digital input DI4 (10.02 DI delayed status, bit 3). 5
DI5 Digital input DI5 (10.02 DI delayed status, bit 4). 6
DI6 Digital input DI6 (10.02 DI delayed status, bit 5). 7
Reserved 8…17
Timed function 1 Bit 0 of 34.01 Timed functions status (see page 191). 18
Timed function 2 Bit 1 of 34.01 Timed functions status (see page 191). 19
Timed function 3 Bit 2 of 34.01 Timed functions status (see page 191). 20
Reserved 21…23
Supervision 1 Bit 0 of 32.01 Supervision status (see page 184). 24
Supervision 2 Bit 1 of 32.01 Supervision status (see page 184). 25
Supervision 3 Bit 2 of 32.01 Supervision status (see page 184). 26
Other [bit] Source selection (see Terms and abbreviations on page 100). -
22.74 Motor
potentiometer down
source
Selects the source of motor potentiometer down signal.
0 = No change
1 = Decrease motor potentiometer value. (If both the up and
down sources are on, the potentiometer value will not
change.)
For the selections, see parameter 22.73 Motor potentiometer
up source.
Not selected
22.75 Motor
potentiometer ramp
time
Defines the change rate of the motor potentiometer. This
parameter specifies the time required for the motor
potentiometer to change from minimum (22.76) to maximum
(22.77). The same change rate applies in both directions.
40.0 s
0.0…3600.0 s Motor potentiometer change time. 10 = 1 s
22.76 Motor
potentiometer min
value
Defines the minimum value of the motor potentiometer.
Note: If vector control mode is used, value of this parameter
must be changed.
-50.00
-32768.00…
32767.00
Motor potentiometer minimum. 1 = 1
22.77 Motor
potentiometer max
value
Defines the maximum value of the motor potentiometer.
Note: If vector control mode is used, value of this parameter
must be changed.
50.00
-32768.00…
32767.00
Motor potentiometer maximum. 1 = 1
22.80 Motor
potentiometer ref
act
The output of the motor potentiometer function. (The motor
potentiometer is configured using parameters 22.7122.74.)
This parameter is read-only.
-
-32768.00…
32767.00
Value of motor potentiometer. 1 = 1
No. Name/Value Description Def/FbEq16