346 Fault tracing
A8A2 RO toggle warning The relay output is changing
states faster than
recommended, eg. if a fast
changing frequency signal is
connected to it. The relay
lifetime will be exceeded
shortly.
Replace the signal connected to the
relay output source with a less
frequently changing signal.
0001 Relay output 1 Select a different signal with parameter
10.24 RO1 source.
0002 Relay output 2 Select a different signal with parameter
10.27 RO2 source.
0003 Relay output 3 Select a different signal with parameter
10.30 RO3 source.
A8B0 ABB Signal
supervision 1
(Editable message text)
Programmable warning:
32.06 Supervision 1
action
Warning generated by the
signal supervision function 1.
Check the source of the warning
(parameter 32.07 Supervision 1 signal).
A8B1
ABB Signal
supervision 2
(Editable message text)
Programmable warning:
32.16 Supervision 2
action
Warning generated by the
signal supervision function 2.
Check the source of the warning
(parameter 32.17 Supervision 2 signal).
A8B2 ABB Signal
supervision 3
(Editable message text)
Programmable warning:
32.26 Supervision 3
action
Warning generated by the
signal supervision function 3.
Check the source of the warning
(parameter 32.27 Supervision 3 signal).
A8B3 ABB Signal
supervision 4
(Editable message text)
Programmable warning:
32.36 Supervision 4
action
Warning generated by the
signal supervision function 4.
Check the source of the warning
(parameter 32.37 Supervision 4 signal).
A8B4 ABB Signal
supervision 5
(Editable message text)
Programmable warning:
32.46 Supervision 5
action
Warning generated by the
signal supervision function 5.
Check the source of the warning
(parameter 32.47 Supervision 5 signal).
A8B5 ABB Signal
supervision 6
(Editable message text)
Programmable warning:
32.56 Supervision 6
action
Warning generated by the
signal supervision function 6.
Check the source of the warning
(parameter 32.57 Supervision 6 signal).
A8BE ULC overload
warning
Programmable fault:
37.03 ULC overload
actions
Selected signal has exceeded
the user overload curve.
Check for any operating conditions
increasing the monitored signal (for
example, the loading of the motor if the
torque or current is being monitored).
Check the definition of the load curve
(parameter group 37 User load curve).
Code
(hex)