ACS550 User’s Manual 67
Control panels
Parameter mode
In the Parameter mode, you can:
view and change parameter values
select and modify the signals shown in the Output mode
start, stop, change the direction and switch between local and remote control.
How to select a parameter and change its value
Step Action Display
1. Go to the Main menu by pressing if you are in the Output mode,
otherwise by pressing repeatedly until you see MENU at the bottom.
2. If the panel is not in the Parameter mode (“PAr” not visible), press key
or until you see “PAr” and then press . The display
shows the number of one of the parameter groups.
3. Use keys and to find the desired parameter group.
4. Press . The display shows one of the parameters in the selected
group.
5. Use keys and to find the desired parameter.
6. Press and hold for about two seconds until the display shows the
value of the parameter with underneath indicating that changing of the
value is now possible.
Note: When is visible, pressing keys and
simultaneously changes the displayed value to the default value of the
parameter.
7. Use keys and to select the parameter value. When you have
changed the parameter value, starts flashing.
To save the displayed parameter value, press .
To cancel the new value and keep the original, press .
LOC
MENU FWD
rEF
LOC
MENU FWD
PAr
LOC
PAR FWD
-01-
LOC
PAR FWD
-11-
LOC
PAR FWD
1101
LOC
PAR FWD
1103
SET
SET
LOC
PAR SET FWD
1
SET
LOC
PAR SET FWD
2
LOC
PAR FWD
1103

Table of Contents

Other manuals for ABB ACS550

Related product manuals