Parameters 367
46.23 At torque hysteresis Defines the “at setpoint” limits for torque control of the drive.
When the absolute difference between reference (26.73
Torque reference act 4) and actual torque (01.10 Motor
torque) is smaller than 46.23 At torque hysteresis, the drive is
considered to be “at setpoint”. This is indicated by bit 8 of
06.11 Main status word.
10.0%
0.0 … 300.0% Limit for “at setpoint” indication in torque control. See par.
46.03
46.31 Above speed limit Defines the trigger level for above limit” indication in speed
control. When actual speed exceeds the limit, bit 10 of 06.17
Drive status word 2 is set.
1500.00 rpm
0.00 … 30000.00
rpm
“Above limit” indication trigger level for speed control. See par.
46.01
46.32 Above frequency
limit
Defines the trigger level for above limit” indication in
frequency control. When actual frequency exceeds the limit,
bit 10 of 06.17 Drive status word 2 is set.
50.00 Hz
0.00 … 1000.00 Hz “Above limit” indication trigger level for frequency control. See par.
46.02
46.33 Above torque limit Defines the trigger level for above limit” indication in torque
control. When actual torque exceeds the limit, bit 10 of 06.17
Drive status word 2 is set.
300.0%
0.0 … 1600.0% “Above limit” indication trigger level for torque control. See par.
46.03
46.42 Torque decimals Defines the number of decimal places of torque-related
parameters.
1
0…2 Number of decimal places of torque parameters. 1 = 1
No. Name/Value Description Def/FbEq16
01.10 (%)
0 %
26.73 + 46.23 (%)
26.73 (%)
26.73 - 46.23 (%)
Drive at setpoint
(06.11 bit 8 = 1)

Table of Contents