1500 m
1000 m
+25 °C +30 °C
+77 °F +86 °F
+40 °C
+104 °F
+35 °C
+95 °F
+20 °C
+68 °F
3300 ft
4921 ft
2000 m
6562 ft
2500 m
8202 ft
3000 m
9842 ft
3500 m
11429 ft
4000 m
13123 ft
1.00
0.95
0.85
0.90
0.80
Derating factor 1.00
Derating factor 0.95
Derating factor 0.90
Derating factor 0.85
Derating factor 0.80
For a more accurate derating, use the DriveSize PC tool.
Inverter modules used, DC fuses, DC capacitances
DC capacit-
ance
Module-specific DC fusesInverter module(s) used
Inverter unit type
μFTypeQtyTypeQty
U
N
= 400 V
280*Cooper Bussmann FWP-10A14F2ACS880-107-004A8-31ACS880-107-004A8-3
280*Cooper Bussmann FWP-10A14F2ACS880-104-006A0-31ACS880-107-006A0-3
280*Cooper Bussmann FWP-15A14F2ACS880-104-008A0-31ACS880-107-008A0-3
435*Cooper Bussmann FWP-20A14F2ACS880-104-0011A-31ACS880-107-0011A-3
865*Cooper Bussmann FWP-25A14F2ACS880-104-0014A-31ACS880-107-0014A-3
865*Cooper Bussmann FWP-32A14F2ACS880-104-0018A-31ACS880-107-0018A-3
785*Mersen 6,921 CP URQ 27x60/502ACS880-104-0025A-31ACS880-107-0025A-3
785*Mersen 6,921 CP URQ 27x60/632ACS880-104-0035A-31ACS880-107-0035A-3
1178*Mersen 6,921 CP URQ 27x60/802ACS880-104-0044A-31ACS880-107-0044A-3
1178*Mersen 6,921 CP URQ 27x60/1002ACS880-104-0050A-31ACS880-107-0050A-3
1570*Mersen 6,921 CP URQ 27x60/1252ACS880-104-0061A-31ACS880-107-0061A-3
136 Technical data