Parameters 405
200.223 Safety fieldbus
adapter slot
Sets the slot in which the safety fieldbus
adapter is installed.
Note: The slots on the drive control board
are defined by drive parameters 50.01 (FBA
A) and 50.31 (FBA B). See the drive
firmware manual.
FBA A
FBA A The safety fieldbus adapter is in slot FBA A.
FBA B The safety fieldbus adapter is in slot FBA B.
200.231 FSE 3X act and par
version
Activates or deactivates the FSE-3x encoder
interface and shows the version of the
encoder parameter groups (includes groups
91 Enc module settings and 92 Encoder 1
configuration).
Disabled
Disabled Deactivates the FSE-3x encoder interface.
Version 1 Activates the FSE-3x encoder interface.
200.232 Number of encoders Sets the number of encoders that are
connected to the FSE module and, in the
single encoder case, also the channel that it
is connected to.
Note: ACS880 primary control program,
version 2.21 supports only one safety pulse
encoder.
Note: DCS880 firmware version 2.07
supports only one safety pulse encoder.
This parameter is read-only.
Single
encoder
CH1
Single encoder CH1
200.254 CRC of the
configuration
Shows the FSO configuration checksum. 0
0…65535 Checksum
FSOGEN
General FSO parameters
FSOGEN.01 FSO general
settings version
Shows the version of the FSO general
parameter group (includes parameter
groups FSOGEN and SAFEIO and
parameters SLSx.02, SLSx.03, SLSx.04,
SARx.02).
Version 1
Version 1 Version 1.
FSOGEN.11 Stop completed
output
Sets the digital output that indicates the
completion of any stop function. Active when
the FSO module has completed the STO,
SSE or SS1 function.
None
None No input connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8