6146/6156 DC Voltage/Current Generators Operation Manual
5.8.3 Remote Command List
5-36
Sweep
Bias value
SB
±data
Sweep bias value setting
*1
Values for the currently selected function are set.
0mV
0mA
23.0
°C
SB?
Query of the sweep bias value
*2
Response: SB
±data
RTB
(Return To Bias)
RB0 OFF (Stays at the stop value when sweep stops.)
()
RB1 ON (Returns to the bias value when sweep stops.)
RB? Query of the RTB
Response: RB0 or RB1
Step time SPdd.dd
Step time setting
*3
SPdd.d dd.d: 0.02 to 10.00 (unit: sec)
0.1
()
SP?
Query of the step time
*3
Response: SPdd.dd
Sweep mode SCM0
Hold sweep mode
*3
()
SCM1 Single sweep mode
SCM2 Repeat sweep mode
SCM?
Query of the sweep mode
*3
Response: SCM0 to SCM2
Sweep start *TRG
Hold sweep:
*3
Executes the sweep by one step.
Single/repeat sweep:
Starts or pauses the sweep.
Sweep stop SWSP
Stops the sweep.
*3
*1: The setting range of the source value varies depending on the model, range or function. For more information, refer to Chapter 8, "SPEC-
IFICATIONS."
*2: The number of digit and the position of the decimal point vary depending on the model, range or function. For more information, refer to
Section 5.7, "Source Value Output Format (Talker Format)."
*3: These commands, which are already described as memory items, are described repeatedly for the purpose of explanation.
Class Item Command Description
Default Operation
Power
ON
Factory
shipment
Memory Sweep

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADCMT 6146 and is the answer not in the manual?

ADCMT 6146 Specifications

General IconGeneral
BrandADCMT
Model6146
CategoryPortable Generator
LanguageEnglish

Related product manuals